50 registri

LenScalaEndian
40520
AC-Current
AC-Current
ac_current3uint1611AR
40521
Phase-A-Current
Phase-A-Current
phase_a_current3uint1611AR
40522
Phase-B-Current
Phase-B-Current
phase_b_current3uint1611AR
40523
Phase-C-Current
Phase-C-Current
phase_c_current3uint1611AR
40524
Scale-factor-[A_SF]
Scale-factor-[A_SF]
scale_factor_a_sf3int1611R
40525
Phase-Voltage-AB
Phase-Voltage-AB
phase_voltage_ab3uint1611VR
40526
Phase-Voltage-BC
Phase-Voltage-BC
phase_voltage_bc3uint1611VR
40527
Phase-Voltage-CA
Phase-Voltage-CA
phase_voltage_ca3uint1611VR
40528
Phase-Voltage-AN
Phase-Voltage-AN
phase_voltage_an3uint1611VR
40529
Phase-Voltage-BN
Phase-Voltage-BN
phase_voltage_bn3uint1611VR
40530
Phase-Voltage-CN
Phase-Voltage-CN
phase_voltage_cn3uint1611VR
40531
Scale-factor-[V_SF]
Scale-factor-[V_SF]
scale_factor_v_sf3int1611R
40532
AC-Power
AC-Power
ac_power3int1611WR
40533
Scale-factor-[W_SF]
Scale-factor-[W_SF]
scale_factor_w_sf3int1611R
40534
Line-Frequency
Line-Frequency
line_frequency3uint1611HzR
40535
Scale-factor-[HZ_SF]
Scale-factor-[HZ_SF]
scale_factor_hz_sf3int1611R
40536
AC-Apparent-Power
AC-Apparent-Power
ac_apparent_power3int1611VAR
40537
Scale-factor-[VA_SF]
Scale-factor-[VA_SF]
scale_factor_va_sf3int1611R
40538
AC-Reactive-Power
AC-Reactive-Power
ac_reactive_power3int1611varR
40539
Scale-factor-[VAR_SF]
Scale-factor-[VAR_SF]
scale_factor_var_sf3int1611R
40540
AC-Power-Factor
AC-Power-Factor
ac_power_factor3int1611PctR
40541
Scale-factor-[PF_SF]
Scale-factor-[PF_SF]
scale_factor_pf_sf3int1611R
40542
AC-Energy
AC-Energy
ac_energy3uint3221WhR
40544
Scale-factor-[WH_SF]
Scale-factor-[WH_SF]
scale_factor_wh_sf3int1611R
40545
DC-Current
DC-Current
dc_current3uint1611AR
40546
Scale-factor-[DCA_SF]
Scale-factor-[DCA_SF]
scale_factor_dca_sf3int1611R
40547
DC-Voltage
DC-Voltage
dc_voltage3uint1611VR
40548
Scale-factor-[DCV_SF]
Scale-factor-[DCV_SF]
scale_factor_dcv_sf3int1611R
40549
DC-Power
DC-Power
dc_power3int1611WR
40550
Scale-factor-[DCW_SF]
Scale-factor-[DCW_SF]
scale_factor_dcw_sf3int1611R
40551
Cabinet-Temperature
Cabinet-Temperature
cabinet_temperature3int1611CR
40552
Heat-Sink-Temperature
Heat-Sink-Temperature
heat_sink_temperature3int1611CR
40553
Transformer-Temperature
Transformer-Temperature
transformer_temperature3int1611CR
40554
Other-Temperature
Other-Temperature
other_temperature3int1611CR
40555
Scale-factor-[TMP_SF]
Scale-factor-[TMP_SF]
scale_factor_tmp_sf3int1611R
40556
Enumerated-value.--Operating-state
Enumerated-value.--Operating-state
enumerated_value_operating_state3uint1611R
40557
Vendor-specific-operating-state-code
Vendor-specific-operating-state-code
vendor_specific_operating_state_code3uint1611R
40558
Bitmask-value.-Event-fields
Bitmask-value.-Event-fields
bitmask_value_event_fields3uint3221R
40560
Reserved-for-future-use
Reserved-for-future-use
reserved_for_future_use3uint3221R
40562
Vendor-defined-events
Vendor-defined-events
vendor_defined_events3uint3221R
40564
Vendor-defined-events
Vendor-defined-events
vendor_defined_events_405643uint3221R
40566
Vendor-defined-events
Vendor-defined-events
vendor_defined_events_405663uint3221R
40568
Vendor-defined-events
Vendor-defined-events
vendor_defined_events_405683uint3221R
40630
Type-of-DER-device.-Default-value-is-4-to-indicate-PV-device.
Type-of-DER-device.-Default-value-is-4-to-indicate-PV-device.
type_of_der_device_default_value_is_4_to_indicate_pv_device3uint1611R
40631
Continuous-power-output-capability-of-the-inverter.
Continuous-power-output-capability-of-the-inverter.
continuous_power_output_capability_of_the_inverter3uint1611WR
40632
Scale-factor
Scale-factor
scale_factor3int1611R
40633
Continuous-Volt-Ampere-capability-of-the-inverter.
Continuous-Volt-Ampere-capability-of-the-inverter.
continuous_volt_ampere_capability_of_the_inverter3uint1611VAR
40634
Scale-factor
Scale-factor
scale_factor_406343int1611R
40635
Continuous-VAR-capability-of-the-inverter-in-quadrant-1.
Continuous-VAR-capability-of-the-inverter-in-quadrant-1.
continuous_var_capability_of_the_inverter_in_quadrant_13int1611varR
40636
Continuous-VAR-capability-of-the-inverter-in-quadrant-2.
Continuous-VAR-capability-of-the-inverter-in-quadrant-2.
continuous_var_capability_of_the_inverter_in_quadrant_23int1611varR

Leggi questi registri via API