BusBabel

huawei SUN2000 8-28KTL

SUN2000 8-28KTL

Importata da documento

Mappa registri Modbus

103 registri

LenScalaEndian
40002
Grid code
Range 0-23.
grid_code3uint1611R/W
40004
MPPT setting
0=Disable, 1=Enable.
mppt_setting3uint1611R/W
40006
Level-1 UF prot.
Range 85%-100%Fn.
level_1_uf_prot3uint1610.01HzR/W
40007
Level-1 UF prot. time
Range 50-600000.
level_1_uf_prot_time3uint3221msR/W
40009
Level-2 UF prot.
Range 85%-100%Fn.
level_2_uf_prot3uint1610.01HzR/W
40010
Level-2 UF prot. time
Range 50-600000.
level_2_uf_prot_time3uint3221msR/W
40012
10-min OV protec.
Range 100%-140%Vn.
10_min_ov_protec3uint1610.01VR/W
40013
10-min OV protec. time
Range 50-600000.
10_min_ov_protec_time3uint3221msR/W
40015
MPPT scanning interval
Range 5-30.
mppt_scanning_interval3uint1611minR/W
40022
Insulation res. protec.
Range 0.033-1.
insulation_res_protec3uint1610.001R/W
40023
Unbal. volt. protec.
Range 0-50.
unbal_volt_protec3uint1610.1%R/W
40032
Reactive power compensation (cosψ-P) trigger voltage
Range 100-110.
reactive_power_compensation_cos_p_trigger_voltage3uint1611%R/W
40033
Reactive power compensation (cosψ-P) exit voltage
Range 90-100.
reactive_power_compensation_cos_p_exit_voltage3uint1611%R/W
40034
Overfrequency deration trigger threshold
Range 50-52.
overfrequency_deration_trigger_threshold3uint1610.01HzR/W
40035
Overfrequency deration exit threshold
Range 49.9-51.
overfrequency_deration_exit_threshold3uint1610.01HzR/W
40036
Overfrequency deration recovery gradient
Range 5-20.
overfrequency_deration_recovery_gradient3uint1611%/minR/W
40037
Q-U characteristic curve mode
Range 0-1.
q_u_characteristic_curve_mode3uint1611R/W
40038
Q-U dispatch trigger power percent
Range 10-100.
q_u_dispatch_trigger_power_percent3uint1611%R/W
40041
Soft startup time after grid failure
Range 20-800.
soft_startup_time_after_grid_failure3uint1611sR/W
40051
LVRT
00=Disable, 01=Enable.
lvrt3uint1611R/W
40052
Enable islanding detection setting
00=Disable, 01=Enable.
enable_islanding_detection_setting3uint1611R/W
40053
Soft start time
Range 20-800.
soft_start_time3uint1611sR/W
40054
Level-1 OV prot.
Range 100%-140%Vn.
level_1_ov_prot3uint1610.01VR/W
40055
Level-1 OV prot. time
Range 50-600000.
level_1_ov_prot_time3uint3221msR/W
40057
Level-2 OV prot.
Range 100%-140%Vn.
level_2_ov_prot3uint1610.01VR/W
40058
Level-2 OV prot. time
Range 50-600000.
level_2_ov_prot_time3uint3221msR/W
40060
Level-1 UV prot.
Range 10%-100%Vn.
level_1_uv_prot3uint1610.01VR/W
40061
Level-1 UV prot. time
Range 50-600000.
level_1_uv_prot_time3uint3221msR/W
40063
Level-2 UV prot.
Range 10%-100%Vn.
level_2_uv_prot3uint1610.01VR/W
40064
Level-2 UV prot. time
Range 50-600000.
level_2_uv_prot_time3uint3221msR/W
40066
Level-1 OF prot.
Range 100%-115%Fn.
level_1_of_prot3uint1610.01HzR/W
40067
Level-2 OF prot. time (nome cosi' nel documento)
Range 50-600000. ATTENZIONE: il documento chiama questo registro "Level-2 OF prot. time" ma la sua posizione (subito dopo Level-1 OF prot. a 40066, prima di Level-2 OF prot. a 40069) suggerisce che sia in realta' il tempo di Level-1. Trascritto cosi' com'e' nel documento originale.
level_2_of_prot_time_nome_cosi_nel_documento3uint3221msR/W
40069
Level-2 OF prot.
Range 100%-115%Fn.
level_2_of_prot3uint1610.01HzR/W
40070
Level-2 OF prot. time
Range 50-600000.
level_2_of_prot_time3uint3221msR/W
40076
Feed grid recovery time
Range 10-600.
feed_grid_recovery_time3uint1611sR/W
40117
Reactive power compensation
0=Disable reactive power output, 1=Communication adjustment power factor, 2=Parameter setting Q/S, 3=Parameter setting power factor, 4=Q(u) characteristic curve, 5=Power factor characteristic curve.
reactive_power_compensation3uint1611R/W
40118
Active power control
0=Disable active power limiting, 1=Communication limit percentage(%), 2=Parameter setting absolute value kW, 3=Parameter setting percentage setting[fixed value].
active_power_control3uint1611R/W
40119
Active power deration setting [percentage]
Range 0-100.
active_power_deration_setting_percentage3uint1611%R/W
40120
Active power deration setting [fixed value]
Range 0-22.
active_power_deration_setting_fixed_value3uint1610.1kWR/W
40121
Active power deration gradient
Range 0.5-10.
active_power_deration_gradient3uint1610.1%/sR/W
40122
Reactive power compensation setting [power factor]
0 <= |a| <= 1.
reactive_power_compensation_setting_power_factor3int1610.001R/W
40123
Reactive power compensation setting [Q/S]
-1 to 1.
reactive_power_compensation_setting_q_s3int1610.001R/W
40124
Reactive power adjustment time
Range 5-120.
reactive_power_adjustment_time3uint1611sR/W
40200
Power on
Comando, valore fisso 0.
power_on6uint1611W
40201
Power off
Comando, valore fisso 0.
power_off6uint1611W
40234
Active power deration percent
Range 0-100.
active_power_deration_percent6uint1611%W
40237
Reactive power compensation factor instruction
-1 to 1.
reactive_power_compensation_factor_instruction6int1610.001W
40500
PV1 Voltage
Per tutte le classi di potenza.
pv1_voltage3int1610.1VR
40501
PV2 Voltage
Per tutte le classi di potenza.
pv2_voltage3int1610.1VR
40502
PV3 Voltage
Per tutte le classi di potenza.
pv3_voltage3int1610.1VR
40503
PV4 Voltage
Per tutte le classi di potenza.
pv4_voltage3int1610.1VR
40504
PV5 Voltage
Per tutte le classi di potenza.
pv5_voltage3int1610.1VR
40505
PV6 Voltage
Per tutte le classi di potenza.
pv6_voltage3int1610.1VR
40506
PV1 Current
Per tutte le classi di potenza.
pv1_current3int1610.01AR
40507
PV2 Current
Per tutte le classi di potenza.
pv2_current3int1610.01AR
40508
PV3 Current
Per tutte le classi di potenza.
pv3_current3int1610.01AR
40509
PV4 Current
Per tutte le classi di potenza.
pv4_current3int1610.01AR
40510
PV5 Current
Per tutte le classi di potenza.
pv5_current3int1610.01AR
40511
PV6 Current
Per tutte le classi di potenza.
pv6_current3int1610.01AR
40523
CO2 reduction
co2_reduction3uint3220.01kgR
40525
Active power
active_power3int3220.001kWR
40527
Uab
uab3uint1610.01VR
40528
Ubc
ubc3uint1610.01VR
40529
Uca
uca3uint1610.01VR
40532
Power factor
power_factor3int1610.001R
40533
Cabinet temperature
cabinet_temperature3int1610.1°CR
40544
Reactive output power
reactive_output_power3int3220.001kVarR
40546
Frequency
frequency3uint1610.01HzR
40560
E-Total
e_total3uint3220.01kWhR
40562
Current-day yield
current_day_yield3uint3220.01kWhR
40572
Ia
ia3int1610.01AR
40573
Ib
ib3int1610.01AR
40574
Ic
ic3int1610.01AR
40613
Inverter start time
inverter_start_time3uint3221sR
40615
Inverter shutdown time
inverter_shutdown_time3uint3221sR
40685
Inverter efficiency
inverter_efficiency3uint1610.01%R
40686
MPPT1 total input power
mppt1_total_input_power3uint3220.001kWR
40688
MPPT2 total input power
mppt2_total_input_power3uint3220.001kWR
40690
MPPT3 total input power
mppt3_total_input_power3uint3220.001kWR
40692
Total input power
total_input_power3uint3220.001kWR
40696
Zero voltage ride through protection
0=no, 1=yes.
zero_voltage_ride_through_protection3uint1611R
40697
LVRT protection
0=no, 1=yes.
lvrt_protection3uint1611R
40698
Anti-islanding
0=no, 1=yes.
anti_islanding3uint1611R
40699
Locking
0=lock, 1=not lock.
locking3uint1611R
40710
Rated inverter power
Codice modello. Vedi tabella "Mapping Between Inverter Models and Rated Power" nel documento originale: 0=20KTL, 1=17KTL, 2=15KTL, 3=12KTL, 4=10KTL, 5=8KTL, 9=500KTL, 16=24.5KTL, 17=23KTL, 18=28KTL, 19=33KTL, 20=40KTL.
rated_inverter_power3uint1611R
40713
ESN
Stringa ASCII multi-registro (MLD), 10 registri.
esn3string1R
40789
Hardware version
Stringa ASCII multi-registro (MLD), 15 registri.
hardware_version3string1R
40819
Software version
Stringa ASCII multi-registro (MLD), 15 registri.
software_version3string1R
40834
ModBus protocol version
Stringa ASCII multi-registro (MLD), 15 registri.
modbus_protocol_version3string1R
40931
Inverter on/off status
Bit1: 1=grid-tied, 0=shutdown.
inverter_on_off_status3bitfield11R
40939
Inverter status
0x0000=Idle:Initializing, 0x0001=Idle:ISO Detecting, 0x0002=Idle:Irradiation Detecting, 0x0100=Starting, 0x0200=On-grid, 0x0201=On-grid:Limited, 0x0300=Shutdown:Abnormal, 0x0301=Shutdown:Forced, 0x0401=Grid Dispatch:cosψ-P Curve, 0x0402=Grid Dispatch:Q-U Curve, 0xA000=Idle:No Irradiation.
inverter_status3uint1611R
40000
Date and time synchronization
Range 0-3155759999.
date_and_time_synchronization3uint3221R/W
50000
Alarm word (0x50000)
bit0x01 Abnormal String1(AlarmID106,CauseID1,Warning); bit0x02 Abnormal String2(107,1,Warning); bit0x03 Abnormal String3(108,1,Warning); bit0x04 Abnormal String4(109,1,Warning); bit0x05 Abnormal String5(110,1,Warning); bit0x06 Abnormal String6(111,1,Warning); bit0x0A Software Ver. Unmatch(504,1,Minor); bit0x0C Upgrade Failed(505,1,Major); bit0x0D Flash Fault(61440,1,Minor).
alarm_word_0x500003bitfield11R
50001
Alarm word (0x50001)
bit0x01 Software Ver. Unmatch(504,2,Minor); bit0x02 Software Ver. Unmatch(504,3,Minor); bit0x03 System Fault(400,1,Major); bit0x06 Abnormal Inv. Circuit(202,20,Major); bit0x07 Abnormal Resid. Cur.(318,1,Major); bit0x08 Cabinet Overtemp.(321,1,Major); bit0x09 Cabinet Overtemp.(321,2,Major); bit0x0F System Fault(400,5,Major).
alarm_word_0x500013bitfield11R
50002
Alarm word (0x50002)
bit0x00 Low Insulation Res.(313,1,Major); bit0x06 Cabinet Overtemp.(321,6,Major); bit0x09 String 3 Reversed(122,1,Warning); bit0x0F System Fault(400,23,Major).
alarm_word_0x500023bitfield11R
50003
Alarm word (0x50003)
bit0x01 String1 Reversed(120,1,Warning); bit0x02 String2 Reversed(121,1,Warning); bit0x06 String4 Reversed(123,1,Warning); bit0x07 String5 Reversed(124,1,Warning); bit0x08 String6 Reversed(125,1,Warning); bit0x09 High DC Input Volt.(103,1,Major); bit0x0A High DC Input Volt.(103,2,Major); bit0x0B High DC Input Volt.(103,3,Major).
alarm_word_0x500033bitfield11R
50004
Alarm word (0x50004)
bit0x01 Cabinet Overtemp.(321,14,Major); bit0x02 String1 Reversed(120,2,Warning); bit0x03 String2 Reversed(121,2,Warning); bit0x0C String3 Reversed(122,2,Warning); bit0x0D String4 Reversed(123,2,Warning); bit0x0E String5 Reversed(124,2,Warning); bit0x0F String6 Reversed(125,2,Warning).
alarm_word_0x500043bitfield11R
50005
Alarm word (0x50005)
bit0x01 Abnormal DC Circuit(200,3,Major); bit0x02 Abnormal Auxiliary Power Supply(410,4,Major); bit0x04 Abnormal DC Circuit(200,10,Major); bit0x05 Abnormal DC Circuit(200,11,Major).
alarm_word_0x500053bitfield11R
50006
Alarm word (0x50006)
bit0x00 Abnormal Inv. Circuit(202,4,Major); bit0x06 System Fault(400,3,Major); bit0x0A Abnormal Inv. Circuit(202,13,Major); bit0x0C Abnormal Inv. Circuit(202,14,Major).
alarm_word_0x500063bitfield11R
50007
Alarm word (0x50007)
bit0x01 Abnormal Inv. Circuit(202,16,Major); bit0x04 Anti-islanding(300,1,Warning); bit0x05 System Fault(400,21,Major); bit0x07 Abnormal Grid Volt. AB<lower(301,7,Major); bit0x08 Abnormal Grid Volt. BC<lower(301,8,Major); bit0x09 Abnormal Grid Volt. CA<lower(301,9,Major).
alarm_word_0x500073bitfield11R
50008
Alarm word (0x50008)
bit0x00 Grid Volt. A<lower(301,4,Major); bit0x01 Grid Volt. B<lower(301,5,Major); bit0x02 Grid Volt. C<lower(301,6,Major); bit0x03 Grid Volt. A>upper(301,16,Major); bit0x04 Grid Volt. B>upper(301,17,Major); bit0x05 Grid Volt. C>upper(301,18,Major); bit0x06 Grid freq>standard(305,2,Major); bit0x07 Grid freq<standard(305,4,Major); bit0x08 Grid 3-phase voltage diff(301,28,Major); bit0x09 Grid fail/AC disconnected(301,29,Major); bit0x0A Abnormal Ground.(326,1,Major); bit0x0B Grid Volt.>upper threshold(301,26,Major).
alarm_word_0x500083bitfield11R
50009
Alarm word (0x50009)
bit0x00 Output A phase low impedance/short(301,31,Major); bit0x01 Output B phase low impedance/short(301,32,Major); bit0x02 Output C phase low impedance/short(301,33,Major); bit0x06 System Fault(400,11,Major); bit0x08 Grid Volt. above 10-min OV threshold(301,19,Major).
alarm_word_0x500093bitfield11R
50011
Alarm word (0x50011)
bit0x0A AB line voltage>upper(301,20,Major); bit0x0B BC line voltage>upper(301,21,Major); bit0x0C CA line voltage>upper(301,22,Major).
alarm_word_0x500113bitfield11R

Leggi questi registri via API

curl https://busbabel.vercel.app/api/devices/huawei/sun2000-8-28ktl/registers?version=v1