DEIF AGC 150
AGC 150
DEIF AGC 150 (plc, controllori e i/o) ha una mappa Modbus di 4167 registri. Function code usati: 1 (coil), 2 (discrete input), 3 (holding register), 4 (input register). Tipi di dato: boolean, int16, int32, string, uint16, uint32. Esempi: Remote start all'indirizzo 0 (FC 1, boolean); GB position ON all'indirizzo 0 (FC 2, boolean); Power regulator setpoint - 0...100% of nominal power. Activated in menu 7501 all'indirizzo 0 (FC 3, int16); Remote GB ON all'indirizzo 1 (FC 1, boolean).
PLC, controllori e I/ODa documento
Mappa registri Modbus
10 registri
- FC
- 1
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- W
- FC
- 2
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- int16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 1
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- W
- FC
- 2
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- int16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 1
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- W
- FC
- 3
- Tipo
- int16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 1
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- W
- FC
- 2
- Tipo
- boolean
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | Remote start Controller types: GEN, GEN-H, ENG. On ATS: Remote start genset-1 (gen/mains application). | remote_start | 1 | boolean | 1 | 1 | — | W | big | |
| 0 | GB position ON Controller types: GEN, GEN-H. On MAINS: TB position ON. On BTB: BTB position ON. | gb_position_on | 2 | boolean | 1 | 1 | — | R | big | |
| 0 | Power regulator setpoint - 0...100% of nominal power. Activated in menu 7501 Controller types: MAINS, GEN, GEN-H. | power_regulator_setpoint_0_100_of_nominal_power_activated_in_menu_7501 | 3 | int16 | 1 | 1 | — | R/W | big | |
| 1 | Remote GB ON Controller types: GEN, GEN-H. On MAINS: Remote TB ON. On ATS: Remote CB1 ON. On BTB: Remote BTB ON. | remote_gb_on | 1 | boolean | 1 | 1 | — | W | big | |
| 1 | MB position ON Controller types: MAINS, GEN, GEN-H. | mb_position_on | 2 | boolean | 1 | 1 | — | R | big | |
| 1 | cosPhi regulator setpoint - 60...100 stated as cosPhi value/100. The value 100 means cosPhi = 1.00 Activated in menu … cosPhi regulator setpoint - 60...100 stated as cosPhi value/100. The value 100 means cosPhi = 1.00 Activated in menu 7504 — Controller types: GEN, GEN-H. | cosphi_regulator_setpoint_60_100_stated_as_cosphi_value_100_the_value_100_means_cosphi_1_00_activated_in_menu | 3 | int16 | 1 | 1 | — | R/W | big | |
| 2 | Remote GB OFF Controller types: GEN, GEN-H. On ATS: Remote CB1 OFF. On MAINS: Remote TB OFF. On BTB: Remote BTB OFF. | remote_gb_off | 1 | boolean | 1 | 1 | — | W | big | |
| 2 | Reactive power regulator setpoint - +/-100% of nominal power. A negative value means capacitive reactive power, and a… Reactive power regulator setpoint - +/-100% of nominal power. A negative value means capacitive reactive power, and a positive value means inductive reactive power. Activated in menu 7505 — Controller types: GEN, GEN-H. | reactive_power_regulator_setpoint_100_of_nominal_power_a_negative_value_means_capacitive_reactive_power_and_a | 3 | int16 | 1 | 1 | — | R/W | big | |
| 3 | Remote stop Controller types: GEN, GEN-H, ENG. On ATS: Remote stop genset-1 (gen/mains application). | remote_stop | 1 | boolean | 1 | 1 | — | W | big | |
| 3 | Running Controller types: GEN, GEN-H, ENG. | running | 2 | boolean | 1 | 1 | — | R | big |
Stai vedendo 10 registri su 4167.